Electromagnetic Induction And Alternating Currents MCQs With Answers – Part 6 (NEET Physics)
GKaim: Measure | Improve | Achieve

Electromagnetic Induction and Alternating Currents MCQs with Answers – Part 6 (NEET Physics)

Timer: Off
Random: Off

501. An ideal transformer has a magnetic core carrying a sinusoidally varying magnetic flux \[ \Phi_B(t)=2.0\times10^{-3}\sin(100t) \] where flux is in webers and time in seconds. The magnetic flux links every turn of both windings. The primary is connected to a sinusoidal source whose RMS voltage is \(100\sqrt2\,\text{V}\). The secondary has an unknown number of turns and is connected across a pure \(20\,\Omega\) resistor. An ideal voltmeter reads \(20\sqrt2\,\text{V}\) RMS across the secondary resistor. Assume negligible winding resistance, leakage flux, core loss and magnetising current. The primary turn count, secondary turn count, and primary RMS current are:
ⓐ. \(500,\ 100,\ \dfrac{2\sqrt2}{5}\,\text{A}\)
ⓑ. \(1000,\ 200,\ \dfrac{\sqrt2}{5}\,\text{A}\)
ⓒ. \(1000,\ 100,\ \dfrac{\sqrt2}{5}\,\text{A}\)
ⓓ. \(1000,\ 200,\ \dfrac{2\sqrt2}{5}\,\text{A}\)
502. An ideal AC generator initially rotates at \(100\,\text{rad s}^{-1}\) and produces a sinusoidal peak emf of \(100\,\text{V}\). It supplies the primary of an ideal transformer having \(200\) primary turns and \(400\) secondary turns. The transformer secondary supplies a pure resistor of \(50\,\Omega\). In a second experiment, the generator rotation speed is doubled without changing its magnetic field or rotating-coil geometry. At the same time, the transformer secondary tapping is changed from \(400\) to \(200\) turns while the primary remains at \(200\) turns. The generator, transformer and mechanical drive remain ideal, and all components have reached sinusoidal steady operation. The ratio of final to initial transformer primary RMS current, ratio of final to initial generator average driving torque, and ratio of final to initial resistor-heating power are:
ⓐ. \(1:2,\ 1:2,\ 1:1\)
ⓑ. \(2:1,\ 1:2,\ 1:1\)
ⓒ. \(1:2,\ 2:1,\ 2:1\)
ⓓ. \(1:1,\ 1:1,\ 1:1\)
503. A practical AC generator rotates uniformly at \(50\,\text{rad s}^{-1}\) and produces a sinusoidal emf of peak magnitude \(100\,\text{V}\). Its winding has an internal resistance of \(10\,\Omega\) and negligible inductance. The generator supplies a variable pure external resistor \(R\). The magnetic field, rotation speed and generated emf remain unchanged as the external resistance is adjusted. Mechanical friction and other generator losses are negligible. The external resistance for maximum useful load power, that maximum power, and the average mechanical driving torque at this condition are:
ⓐ. \(10\,\Omega,\ 250\,\text{W},\ 5.0\,\text{N m}\)
ⓑ. \(20\,\Omega,\ 125\,\text{W},\ 2.5\,\text{N m}\)
ⓒ. \(10\,\Omega,\ 125\,\text{W},\ 2.5\,\text{N m}\)
ⓓ. \(10\,\Omega,\ 125\,\text{W},\ 5.0\,\text{N m}\)
504. Two practical transformers have identical primary and secondary windings, magnetic-core material, core dimensions and operating frequency. Transformer P uses a solid conducting magnetic core. Transformer Q uses thin sheets of the same magnetic material, separated from one another by insulating layers. Both transformers are supplied with the same sinusoidal primary voltage and deliver the same useful real output power. Assume that the laminated core retains essentially the same useful magnetic-flux linkage as the solid core. Consider the following statements. Statement I: The laminated construction can reduce core heating because it restricts large circulating eddy-current paths. Statement II: The insulating layers increase electrical opposition to currents attempting to circulate between adjacent laminations. Statement III: Laminating the core necessarily eliminates hysteresis loss completely because hysteresis requires a closed electrical conduction path. Statement IV: If the winding losses remain unchanged and the core loss decreases, the real input power required for the same useful output can decrease without changing the ideal voltage-turns ratio. Which statements are correct?
ⓐ. I and III only
ⓑ. I, II and IV only
ⓒ. II, III and IV only
ⓓ. I, II, III and IV
505. A rotating-coil AC generator has \(100\) turns, with area \(0.010\,\text{m}^2\) per turn. The coil rotates at constant angular speed \(20\,\text{rad s}^{-1}\) about an axis perpendicular to an applied magnetic field. Unlike the usual elementary generator, the magnetic-field magnitude is itself increasing with time: \[ B(t)=0.50+0.10t \] where \(B\) is in tesla and \(t\) is in seconds. The field direction remains fixed, and the coil's area vector is parallel to the field at \(t=0\). The signed magnetic flux linkage is defined by \[ \lambda(t)=NA B(t)\cos(20t) \] The coil supplies a pure \(10\,\Omega\) resistor, with negligible winding resistance and self-inductance. The signed induced emf at \(t=0\), signed induced emf at \(t=\pi/40\,\text{s}\), and instantaneous resistor-heating power at \(t=0\) are:
ⓐ. \(0,\ 10+\dfrac{\pi}{20}\,\text{V},\ 0\)
ⓑ. \(+0.10\,\text{V},\ 10\,\text{V},\ 1.0\times10^{-3}\,\text{W}\)
ⓒ. \(-0.10\,\text{V},\ 10+\dfrac{\pi}{20}\,\text{V},\ 1.0\times10^{-3}\,\text{W}\)
ⓓ. \(-0.10\,\text{V},\ 10\,\text{V},\ 1.0\times10^{-2}\,\text{W}\)
506. A practical transformer is represented on its secondary side by an ideal sinusoidal emf source in series with an equivalent winding resistance \(r\). Leakage reactance and core losses are neglected, and the induced secondary RMS emf remains \(120\,\text{V}\) for all the load conditions considered. When a pure \(20\,\Omega\) resistor is connected, an ideal voltmeter across the load reads \(100\,\text{V}\) RMS. The load is then replaced by a pure \(8.0\,\Omega\) resistor. The equivalent winding resistance, new secondary terminal RMS voltage, and average winding-heating power in the second experiment are:
ⓐ. \(2.0\,\Omega,\ 96\,\text{V},\ 288\,\text{W}\)
ⓑ. \(4.0\,\Omega,\ 80\,\text{V},\ 800\,\text{W}\)
ⓒ. \(4.0\,\Omega,\ 120\,\text{V},\ 400\,\text{W}\)
ⓓ. \(4.0\,\Omega,\ 80\,\text{V},\ 400\,\text{W}\)
507. An AC generator contains a rigid coil rotating in a uniform magnetic field and supplying a fixed pure resistor. The generator has negligible internal resistance, and its rotational speed is determined by a driving mechanism providing a constant average torque. Mechanical friction and other losses are neglected. In experiment P, the magnetic-field magnitude is \(B\), and the generator reaches steady angular speed \(\omega\). In experiment Q, the magnetic-field magnitude is doubled while the driving mechanism continues supplying the same constant average torque. The generator reaches a new steady angular speed. Assume the generator remains in the ideal sinusoidal operating regime throughout. The ratio of final to initial angular speeds, generated peak emfs and average resistor-heating powers are:
ⓐ. \(1:2,\ 1:1,\ 1:2\)
ⓑ. \(1:4,\ 1:2,\ 1:4\)
ⓒ. \(1:2,\ 2:1,\ 4:1\)
ⓓ. \(1:4,\ 2:1,\ 1:4\)
508. An idealised transformer operates with a linear magnetic core of uniform cross-sectional area and fixed mean magnetic-path length. Its primary winding, secondary winding, supply RMS voltage and supply frequency remain unchanged. The primary source is an ideal sinusoidal voltage source. In experiment P, the core cross-sectional area is \(A\). In experiment Q, the cross-sectional area is increased to \(2A\), while the core material's magnetic permeability and mean magnetic-path length remain unchanged. Assume uniform magnetic flux density, negligible leakage, no saturation, and negligible winding resistance. The primary magnetising inductance is finite and obeys the standard linear magnetic-circuit approximation. Consider the following statements. Statement I: The maximum total core magnetic flux is unchanged because the primary RMS voltage, frequency and primary turn count are fixed. Statement II: The maximum core magnetic flux density becomes half its original value. Statement III: The primary magnetising inductance becomes twice its original value, so the RMS magnetising current becomes half its original value. Statement IV: The RMS secondary induced voltage becomes twice its original value because twice as much core cross-sectional area is available. Which statements are correct?
ⓐ. I and IV only
ⓑ. II, III and IV only
ⓒ. I, II and III only
ⓓ. I, II, III and IV
509. A practical transformer supplies a load at a regulated secondary voltage of \(100\,\text{V}\) RMS. The secondary RMS current is maintained at \(5.0\,\text{A}\) in two separate experiments. In experiment P, the load operates at a lagging power factor of \(0.60\). In experiment Q, the load operates at unity power factor. The transformer's constant core loss is \(20\,\text{W}\), and its total winding loss is \(30\,\text{W}\) in either experiment. Assume these are the only losses, and the stated voltage and current are maintained despite the load changes. The efficiencies in P and Q, and the ratio of total losses in Q to P, are:
ⓐ. \(\dfrac67,\ \dfrac{10}{11},\ 1:1\)
ⓑ. \(\dfrac35,\ 1,\ 1:1\)
ⓒ. \(\dfrac67,\ \dfrac{10}{11},\ 3:5\)
ⓓ. \(\dfrac67,\ \dfrac56,\ 1:1\)
510. A practical transformer's secondary circuit is represented by an internally generated sinusoidal RMS emf of \(100\,\text{V}\) in series with an effective winding resistance of \(2.0\,\Omega\). Leakage reactance, core loss and magnetic saturation are neglected. The primary supply maintains the induced secondary emf during the brief measurements. In experiment P, a pure \(18\,\Omega\) resistor is connected across the secondary output. In experiment Q, the external secondary terminals are connected directly together using a conductor of negligible resistance. Assume the short-circuit measurement is sufficiently brief to avoid thermal damage. The ratio of short-circuit RMS current to the current in P, the short-circuit winding-heating power, and useful external-load power in Q are:
ⓐ. \(5:1,\ 2500\,\text{W},\ 0\)
ⓑ. \(10:1,\ 5000\,\text{W},\ 0\)
ⓒ. \(10:1,\ 5000\,\text{W},\ 5000\,\text{W}\)
ⓓ. \(10:1,\ 2500\,\text{W},\ 0\)
Subscribe
Notify of
guest
0 Comments
Scroll to Top