201. The same scale, with least count \(0.1\,\text{cm}\), is used to measure two lengths of approximately \(2.0\,\text{cm}\) and \(50.0\,\text{cm}\). If the maximum absolute uncertainty is taken as one least count in each measurement, which conclusion is correct?
ⓐ. Both measurements have \(5\%\) percentage uncertainty because the same scale is used.
ⓑ. The \(2.0\,\text{cm}\) measurement has \(5\%\) uncertainty, whereas the \(50.0\,\text{cm}\) measurement has \(0.2\%\) uncertainty.
ⓒ. The larger length has larger percentage uncertainty because its numerical value is larger.
ⓓ. The percentage uncertainty is independent of the measured magnitude whenever the least count is fixed.
Correct Answer: The \(2.0\,\text{cm}\) measurement has \(5\%\) uncertainty, whereas the \(50.0\,\text{cm}\) measurement has \(0.2\%\) uncertainty.
Explanation: Both measurements are assigned the same maximum absolute uncertainty:
\[
\Delta L=0.1\,\text{cm}.
\]
For the smaller length,
\[
\frac{\Delta L}{L}\times100
=\frac{0.1}{2.0}\times100=5\%.
\]
For the larger length,
\[
\frac{\Delta L}{L}\times100
=\frac{0.1}{50.0}\times100=0.2\%.
\]
Thus the same absolute instrumental resolution corresponds to very different relative measurement quality when the measured magnitudes differ. A fixed least count forms a much larger fraction of a small quantity than of a large quantity. Therefore absolute resolution and relative precision must not be confused. Hence option B is correct.
202. Two devices are used repeatedly on an object whose length is near \(50\,\text{mm}\).
| Device | Least count | Displayed readings in mm |
|---|
| P | \(1.0\,\text{mm}\) | \(50,\ 50,\ 50,\ 50\) |
| Q | \(0.1\,\text{mm}\) | \(49.9,\ 50.0,\ 50.1,\ 50.0\) |
Which assessment is correct?
ⓐ. P has infinitely better precision because its mean absolute deviation is zero.
ⓑ. P and Q have identical resolution because both have mean near \(50\,\text{mm}\).
ⓒ. Q must be inaccurate because its readings are not identical.
ⓓ. P's coarse resolution hides variation that Q's finer resolution reveals.
Correct Answer: P's coarse resolution hides variation that Q's finer resolution reveals.
Explanation: Device P displays exactly the same value on every trial, so the mean absolute deviation of its displayed values is indeed zero. However, P has a coarse least count of
\[
1.0\,\text{mm}.
\]
Variations smaller than this may remain invisible in its readings. Device Q has a much smaller least count:
\[
0.1\,\text{mm}.
\]
It can therefore reveal changes of a few tenths of a millimetre that P cannot distinguish. The small spread in Q's readings does not by itself imply poor accuracy; it may simply reveal genuine random variation at a finer resolution. Thus zero displayed scatter from a coarse instrument must not be mistaken for infinitely fine precision. Hence option D is correct.
203. Repeated readings of a quantity are \(10.0,\ 10.1,\ 9.9,\ 11.2\). No independent evidence of a reading, recording or procedural mistake is available. A student immediately deletes \(11.2\) and labels it a gross error only because it lies far from the other values. Which statement is most appropriate?
ⓐ. Do not discard it as a gross error without evidence of an avoidable reading, recording or procedural mistake.
ⓑ. Every reading farthest from the mean is, by definition, a gross error.
ⓒ. Any reading that increases mean absolute error must be discarded.
ⓓ. \(11.2\) must be systematic error because it lies above the other readings.
Correct Answer: Do not discard it as a gross error without evidence of an avoidable reading, recording or procedural mistake.
Explanation: A gross error is associated with an identifiable avoidable mistake such as incorrect reading, recording or procedure. A numerically unusual observation may raise suspicion and should certainly be checked. However, unusual numerical position alone does not prove that a gross mistake occurred. Random fluctuations can produce observations farther from the others, and an unrecognized change in measurement conditions is also possible. Automatically deleting any inconvenient reading would artificially improve the apparent precision of the data. The observer should instead investigate the measurement record, procedure and conditions for independent evidence of a mistake. If such evidence is found, the gross error can be corrected or rejected appropriately. Without that evidence, simply labelling the value as gross is not logically justified. Hence option A is correct.
204. An unchanged reference object is measured under two environmental conditions. Under condition A, readings are \(50.01,\ 50.00,\ 50.02\) units. Under condition B, readings are \(50.31,\ 50.30,\ 50.32\) units. When condition A is restored, readings again return close to \(50.01\) units. Which interpretation best fits the observations?
ⓐ. The shift under B is a gross error because all three B readings are different from the A readings.
ⓑ. The shift is purely random because repeated readings are not exactly identical.
ⓒ. The reproducible shift with condition B indicates a condition-dependent systematic effect, with small random scatter within each set.
ⓓ. Averaging all six readings is sufficient to remove the effect of condition B.
Correct Answer: The reproducible shift with condition B indicates a condition-dependent systematic effect, with small random scatter within each set.
Explanation: Under condition A, the readings cluster close to \(50.01\) units. Under condition B, they form a second tight cluster near \(50.31\) units. When A is restored, the readings return to the original level. Thus the approximately \(0.30\)-unit shift follows the environmental condition in a reproducible manner. Such repeatable condition-linked displacement is characteristic of a systematic effect rather than purely random variation. The small differences among readings inside each cluster represent an additional random component. Nothing in the description indicates an avoidable recording or reading mistake, so a gross-error classification is unsupported. Simply averaging A and B together would mix two differently biased conditions rather than remove the cause. Hence option C is correct.
205. Five repeated readings have arithmetic mean \(20.0\) units. Four of the readings are \(19.8,\ 20.2,\ 20.1,\ 19.9\), and the fifth reading is unknown. What are the missing reading and the mean absolute error?
ⓐ. \(20.2\) and \(0.16\)
ⓑ. \(20.0\) and \(0.12\)
ⓒ. \(19.8\) and \(0.20\)
ⓓ. \(20.0\) and \(0.15\)
Correct Answer: \(20.0\) and \(0.12\)
Explanation: A mean of \(20.0\) for five readings requires a total sum
\[
5(20.0)=100.0.
\]
The four known readings sum to
\[
19.8+20.2+20.1+19.9=80.0.
\]
Hence the missing reading is
\[
100.0-80.0=20.0.
\]
Now calculate the absolute deviations from the mean \(20.0\):
\[
0.2,\ 0.2,\ 0.1,\ 0.1,\ 0.
\]
Their sum is
\[
0.6.
\]
Therefore the mean absolute error is
\[
\Delta x_{\text{mean}}=\frac{0.6}{5}=0.12.
\]
Thus the missing reading is \(20.0\) and the corresponding mean absolute error is \(0.12\). Hence option B is correct.
206. Four repeated length measurements are \(2.01\,\text{m}\), \(2.03\,\text{m}\), \(2.02\,\text{m}\) and \(2.04\,\text{m}\). Using arithmetic mean and mean absolute error, which converted report is correct?
ⓐ. \((202.5\pm1.0)\,\text{cm}\), with percentage error approximately \(0.49\%\)
ⓑ. \((202.5\pm0.1)\,\text{cm}\), with percentage error approximately \(0.05\%\)
ⓒ. \((202.0\pm1.5)\,\text{cm}\), with percentage error approximately \(0.74\%\)
ⓓ. \((2.025\pm1.0)\,\text{cm}\), with percentage error approximately \(49\%\)
Correct Answer: \((202.5\pm1.0)\,\text{cm}\), with percentage error approximately \(0.49\%\)
Explanation: The arithmetic mean is
\[
\bar L=\frac{2.01+2.03+2.02+2.04}{4}\,\text{m}.
\]
Thus,
\[
\bar L=\frac{8.10}{4}\,\text{m}=2.025\,\text{m}.
\]
The absolute deviations are
\[
0.015,\ 0.005,\ 0.005,\ 0.015\,\text{m}.
\]
Their sum is
\[
0.040\,\text{m}.
\]
Hence the mean absolute error is
\[
\Delta L_{\text{mean}}=\frac{0.040}{4}=0.010\,\text{m}.
\]
The elementary report is therefore
\[
L=(2.025\pm0.010)\,\text{m}.
\]
Exact conversion to centimetres gives
\[
L=(202.5\pm1.0)\,\text{cm}.
\]
The percentage error is
\[
\frac{0.010}{2.025}\times100\approx0.49\%.
\]
Hence option A is correct.
207. A measuring system has a fixed additive offset of \(+0.30\,\text{cm}\), meaning every position reading is \(0.30\,\text{cm}\) too high. The two endpoints of an object are read as \(2.80\,\text{cm}\) and \(7.80\,\text{cm}\). A separate direct length reading made by the same biased system gives \(5.30\,\text{cm}\). Which conclusion is correct?
ⓐ. Both methods give \(5.30\,\text{cm}\) because the same offset affects all readings.
ⓑ. Endpoint subtraction gives \(4.70\,\text{cm}\), while the corrected direct reading gives \(5.00\,\text{cm}\).
ⓒ. Endpoint subtraction gives \(5.30\,\text{cm}\), while the direct reading needs no correction.
ⓓ. The common additive offset cancels in the endpoint difference; correcting the direct reading also gives \(5.00\,\text{cm}\).
Correct Answer: The common additive offset cancels in the endpoint difference; correcting the direct reading also gives \(5.00\,\text{cm}\).
Explanation: Let the true endpoint positions be \(x_1\) and \(x_2\). Because the instrument adds \(0.30\,\text{cm}\), its displayed values are
\[
x_1'=x_1+0.30,\qquad x_2'=x_2+0.30.
\]
The measured endpoint difference is therefore
\[
x_2'-x_1'=(x_2+0.30)-(x_1+0.30).
\]
The common offset cancels:
\[
x_2'-x_1'=x_2-x_1.
\]
Numerically,
\[
7.80-2.80=5.00\,\text{cm}.
\]
A direct reading of the length itself, however, is shifted upward by the same offset. Thus,
\[
5.30-0.30=5.00\,\text{cm}.
\]
Therefore the endpoint-difference method eliminates this particular common additive systematic offset automatically, whereas the direct reading requires explicit correction. Hence option D is correct.
208. Two measured lengths are
\[
x=(10.0\pm0.2)\,\text{cm},\qquad y=(14.0\pm0.4)\,\text{cm}.
\]
Their arithmetic mean is defined by
\[
M=\frac{x+y}{2},
\]
where \(2\) is exact. Using maximum-error treatment, which result is correct?
ⓐ. \(M=(12.0\pm0.6)\,\text{cm}\), giving \(5\%\) error
ⓑ. \(M=(12.0\pm0.3)\,\text{cm}\), giving \(2.5\%\) error
ⓒ. \(M=(12.0\pm0.1)\,\text{cm}\), giving approximately \(0.8\%\) error
ⓓ. \(M=(24.0\pm0.6)\,\text{cm}\), giving \(2.5\%\) error
Correct Answer: \(M=(12.0\pm0.3)\,\text{cm}\), giving \(2.5\%\) error
Explanation: First form the measured sum:
\[
S=x+y=10.0+14.0=24.0\,\text{cm}.
\]
For addition, maximum absolute errors add:
\[
\Delta S=0.2+0.4=0.6\,\text{cm}.
\]
The arithmetic mean is
\[
M=\frac{S}{2}.
\]
Because the divisor \(2\) is exact, both the value and maximum absolute error are divided by \(2\):
\[
M=\frac{24.0}{2}=12.0\,\text{cm},
\]
and
\[
\Delta M=\frac{0.6}{2}=0.3\,\text{cm}.
\]
Therefore,
\[
M=(12.0\pm0.3)\,\text{cm}.
\]
Its percentage error is
\[
\frac{0.3}{12.0}\times100=2.5\%.
\]
Hence option B is correct.
209. Two perpendicular measured lengths are
\[
x=(3.00\pm0.03)\,\text{cm},\qquad y=(4.00\pm0.04)\,\text{cm},
\]
and
\[
R=\sqrt{x^2+y^2}.
\]
Using elementary maximum-error rules step by step, what is the approximate result for \(R\)?
ⓐ. \((5.00\pm0.50)\,\text{cm}\)
ⓑ. \((5.00\pm0.10)\,\text{cm}\)
ⓒ. \((5.00\pm0.05)\,\text{cm}\)
ⓓ. \((5.00\pm0.01)\,\text{cm}\)
Correct Answer: \((5.00\pm0.05)\,\text{cm}\)
Explanation: First calculate the nominal squared quantities:
\[
x^2=9.00\,\text{cm}^2,\qquad y^2=16.00\,\text{cm}^2.
\]
For \(x^2\), the fractional error is twice that of \(x\):
\[
\Delta(x^2)=2x\Delta x=2(3.00)(0.03)=0.18\,\text{cm}^2.
\]
Similarly,
\[
\Delta(y^2)=2(4.00)(0.04)=0.32\,\text{cm}^2.
\]
For the sum,
\[
S=x^2+y^2=25.00\,\text{cm}^2,
\]
and maximum absolute errors add:
\[
\Delta S=0.18+0.32=0.50\,\text{cm}^2.
\]
Now,
\[
R=S^{1/2}.
\]
Hence,
\[
\frac{\Delta R}{R}
=\frac12\frac{\Delta S}{S}
=\frac12\left(\frac{0.50}{25.00}\right)=0.010.
\]
Since
\[
R=\sqrt{25.00}=5.00\,\text{cm},
\]
we obtain
\[
\Delta R=(0.010)(5.00)=0.05\,\text{cm}.
\]
Thus \(R\approx(5.00\pm0.05)\,\text{cm}\), so option C is correct.
210. Two lengths are measured as
\[
x=(15.0\pm0.1)\,\text{cm}
\]
and
\[
y=(10.0\pm\Delta y)\,\text{cm}.
\]
The difference \(L=x-y\) must have maximum percentage uncertainty no greater than \(8\%\). What is the largest permissible value of \(\Delta y\)?
ⓐ. \(0.3\,\text{cm}\)
ⓑ. \(0.4\,\text{cm}\)
ⓒ. \(0.5\,\text{cm}\)
ⓓ. \(0.7\,\text{cm}\)
Correct Answer: \(0.3\,\text{cm}\)
Explanation: The nominal difference is
\[
L=15.0-10.0=5.0\,\text{cm}.
\]
An \(8\%\) maximum percentage uncertainty permits an absolute uncertainty of at most
\[
\Delta L_{\max}=\frac{8}{100}(5.0)\,\text{cm}.
\]
Hence,
\[
\Delta L_{\max}=0.4\,\text{cm}.
\]
For a difference, maximum absolute errors add:
\[
\Delta L=\Delta x+\Delta y.
\]
Therefore,
\[
0.1+\Delta y\le0.4.
\]
Thus,
\[
\Delta y\le0.3\,\text{cm}.
\]
The largest permissible uncertainty in the second measurement is therefore \(0.3\,\text{cm}\). This reverse calculation shows how an allowed final percentage error can be used to set an instrumental uncertainty requirement. Hence option A is correct.
211. An instrument has a proportional calibration error. A true value of \(20.0\) units is displayed as \(20.4\) units, and a true value of \(50.0\) units is displayed as \(51.0\) units. The same instrument gives repeated readings \(30.5,\ 30.7,\ 30.6\) units for an unknown quantity. Assuming the proportional calibration factor is constant, which corrected result is obtained using the arithmetic mean and mean absolute error?
ⓐ. \(30.0\pm0.07\) units
ⓑ. \(30.6\pm0.07\) units
ⓒ. \(30.0\pm0.20\) units
ⓓ. \(29.4\pm0.07\) units
Correct Answer: \(30.0\pm0.07\) units
Explanation: The calibration data show that the displayed value is larger than the true value by a constant multiplicative factor. From the first standard,
\[
\frac{20.4}{20.0}=1.02.
\]
The second standard confirms the same factor:
\[
\frac{51.0}{50.0}=1.02.
\]
Thus a displayed value must be divided by \(1.02\) to obtain the corrected value. The mean displayed reading of the unknown quantity is
\[
\bar x_{\text{disp}}=\frac{30.5+30.7+30.6}{3}=30.6.
\]
Hence the corrected mean is
\[
\bar x=\frac{30.6}{1.02}=30.0.
\]
The displayed absolute deviations from \(30.6\) are \(0.1,\ 0.1,\ 0\), so
\[
\Delta x_{\text{disp}}=\frac{0.2}{3}=0.0667.
\]
A multiplicative correction scales the absolute deviations by the same factor:
\[
\Delta x=\frac{0.0667}{1.02}\approx0.065.
\]
Thus the corrected elementary report is approximately
\[
30.0\pm0.07.
\]
Unlike an additive offset, a proportional calibration correction scales both the mean and the absolute scatter. Hence option A is correct.
212. An instrument is used repeatedly while an environmental variable steadily increases. The readings are \(8.00,\ 8.08,\ 8.16,\ 8.24\) units. When the environmental variable is returned to its initial value, the reading returns close to \(8.00\) units. Which interpretation is most appropriate?
ⓐ. The monotonic sequence must be random error because every reading is different.
ⓑ. The instrument becomes more accurate as the number of observations increases.
ⓒ. The final return to \(8.00\) proves that the intermediate readings were gross recording errors.
ⓓ. The pattern is consistent with environment-dependent systematic drift; averaging does not remove its physical cause.
Correct Answer: The pattern is consistent with environment-dependent systematic drift; averaging does not remove its physical cause.
Explanation: Random error normally produces irregular fluctuations whose direction changes unpredictably from reading to reading. Here the readings increase in an ordered sequence as the environmental variable increases. The change is therefore correlated with an external condition rather than behaving like unstructured random scatter. The return of the reading toward \(8.00\) when the condition is restored strengthens the evidence for a repeatable environmental effect. Such condition-dependent displacement is a systematic error pattern. Averaging the four drifting readings would produce a numerical mean, but that mean would still reflect measurements taken under progressively changing bias. Averaging therefore does not remove the physical cause of the drift. Nothing in the stem identifies an incorrect reading or recording procedure, so classification as gross error is unsupported. The appropriate response would be to control or correct the environmental effect. Hence option D is correct.
213. Four repeated measurements of the same length are recorded in different units as \(2.00\,\text{m}\), \(201\,\text{cm}\), \(1990\,\text{mm}\) and \(2.02\,\text{m}\). Using arithmetic mean and mean absolute error, what are the mean length and approximate percentage error?
ⓐ. \(200.5\,\text{cm}\) and \(0.50\%\)
ⓑ. \(200.0\,\text{cm}\) and \(1.0\%\)
ⓒ. \(201.0\,\text{cm}\) and \(0.25\%\)
ⓓ. \(200.5\,\text{cm}\) and \(2.0\%\)
Correct Answer: \(200.5\,\text{cm}\) and \(0.50\%\)
Explanation: The readings must first be placed in the same unit before they are averaged. The four values become
\[
200\,\text{cm},\quad201\,\text{cm},\quad199\,\text{cm},\quad202\,\text{cm}.
\]
Their arithmetic mean is
\[
\bar L=\frac{200+201+199+202}{4}\,\text{cm}.
\]
Thus,
\[
\bar L=200.5\,\text{cm}.
\]
The absolute deviations from the mean are
\[
0.5,\ 0.5,\ 1.5,\ 1.5\,\text{cm}.
\]
Therefore,
\[
\Delta L_{\text{mean}}=\frac{0.5+0.5+1.5+1.5}{4}=1.0\,\text{cm}.
\]
The relative error is
\[
\frac{1.0}{200.5}\approx4.99\times10^{-3}.
\]
Hence the percentage error is approximately
\[
0.50\%.
\]
Exact unit conversion changes neither the physical scatter nor the relative error once all readings are expressed consistently. Hence option A is correct.
214. Four raw readings are \(10.52\,\text{cm}\), \(10.48\,\text{cm}\), \(105.0\,\text{cm}\) and \(10.50\,\text{cm}\). The notebook independently confirms that the third reading was actually \(10.50\,\text{cm}\) and was copied incorrectly. The instrument is also known to have a fixed \(+0.20\,\text{cm}\) calibration offset. After correcting both defects, what are the mean and mean absolute error?
ⓐ. \(10.50\,\text{cm}\) and \(0.01\,\text{cm}\)
ⓑ. \(10.30\,\text{cm}\) and \(0.01\,\text{cm}\)
ⓒ. \(10.30\,\text{cm}\) and \(0.20\,\text{cm}\)
ⓓ. \(10.10\,\text{cm}\) and \(0.02\,\text{cm}\)
Correct Answer: \(10.30\,\text{cm}\) and \(0.01\,\text{cm}\)
Explanation: The independent notebook evidence identifies \(105.0\,\text{cm}\) as a gross recording error. It must first be restored to the verified reading \(10.50\,\text{cm}\). The corrected raw set before calibration correction is therefore
\[
10.52,\ 10.48,\ 10.50,\ 10.50\,\text{cm}.
\]
The instrument reads \(0.20\,\text{cm}\) too high, so subtract this fixed systematic offset from every observation. The fully corrected readings are
\[
10.32,\ 10.28,\ 10.30,\ 10.30\,\text{cm}.
\]
Their mean is
\[
\bar L=\frac{10.32+10.28+10.30+10.30}{4}=10.30\,\text{cm}.
\]
The absolute deviations from this mean are
\[
0.02,\ 0.02,\ 0,\ 0\,\text{cm}.
\]
Hence,
\[
\Delta L_{\text{mean}}=\frac{0.04}{4}=0.01\,\text{cm}.
\]
The gross error and systematic bias are conceptually different corrections, and both must be handled before interpreting the residual random scatter. Hence option B is correct.
215. Repeated measurements of a quantity \(x\) are summarized as
\[
x=5.00\pm0.10,
\]
where \(0.10\) is the mean absolute error. A new reported quantity is defined by the exact calibration relation
\[
y=2x+3.
\]
Which pair correctly gives the mean absolute error in \(y\) and its approximate relative error?
ⓐ. \(0.10\) and \(0.77\%\)
ⓑ. \(0.40\) and \(3.08\%\)
ⓒ. \(0.20\) and \(2.00\%\)
ⓓ. \(0.20\) and \(1.54\%\)
Correct Answer: \(0.20\) and \(1.54\%\)
Explanation: The exact transformation of the mean is
\[
\bar y=2(5.00)+3=13.00.
\]
Consider a deviation \(\delta x\) from the mean of \(x\). The corresponding deviation in \(y\) is
\[
\delta y=2\delta x,
\]
because the additive constant \(3\) cancels when deviations from the mean are taken. Therefore the mean absolute error scales by the exact multiplicative factor:
\[
\Delta y=2(0.10)=0.20.
\]
The relative error in the transformed quantity is then
\[
\frac{\Delta y}{\bar y}=\frac{0.20}{13.00}.
\]
Thus,
\[
\frac{\Delta y}{\bar y}\approx0.01538,
\]
or approximately
\[
1.54\%.
\]
Although the absolute scatter doubles, the added exact constant increases the central value and therefore changes the relative error in a nontrivial way. Hence option D is correct.
216. Two highly reproducible instruments are used on an accepted \(10.0\)-unit standard. Instrument P repeatedly gives \(10.2\) units, while instrument Q repeatedly gives \(9.8\) units. If equal numbers of readings from P and Q are pooled, their combined mean is \(10.0\) units. Which conclusion is correct?
ⓐ. Pooling proves that both instruments are individually accurate.
ⓑ. The opposite systematic biases cancel in the pooled mean, but the individual calibration errors remain.
ⓒ. The pooled mean converts both systematic errors into random errors.
ⓓ. Averaging readings from biased instruments always guarantees the accepted value.
Correct Answer: The opposite systematic biases cancel in the pooled mean, but the individual calibration errors remain.
Explanation: Instrument P has a repeatable positive displacement of
\[
+0.2
\]
unit from the accepted value. Instrument Q has a repeatable negative displacement of
\[
-0.2
\]
unit. Because equal numbers of readings are taken from each instrument, the opposite signed biases cancel numerically in the pooled average. This accidental cancellation makes the pooled central value equal to the accepted value. It does not mean that either instrument has become individually accurate. If P alone were used later, its positive systematic bias would remain. Likewise Q would continue to show its negative bias. Combining biased data sets can therefore conceal calibration problems rather than remove their physical causes. Systematic errors do not become random merely because opposite biases are averaged together. Hence option B is correct.
217. An instrument gives the sequence \(20.0,\ 20.1,\ 20.2,\ 20.3,\ 20.4\) units during continuous operation. After the instrument is switched off, allowed to return to its initial condition, and restarted, the sequence again begins close to \(20.0\) units and rises in the same manner. Which statement is best supported?
ⓐ. The reproducible time-dependent trend indicates systematic drift rather than purely random error.
ⓑ. The readings are random because no two consecutive values are equal.
ⓒ. The final value \(20.4\) must be a gross error and should simply be deleted.
ⓓ. Taking the mean of an arbitrarily long drifting sequence guarantees removal of the drift.
Correct Answer: The reproducible time-dependent trend indicates systematic drift rather than purely random error.
Explanation: A random error pattern would ordinarily show irregular variations without a reproducible directional progression. Here each successive reading rises in a systematic order during operation. More importantly, restarting the experiment reproduces essentially the same trend. Reproducibility of the drift strongly suggests that it is linked to a repeatable physical cause associated with operating time or changing instrument condition. Such behaviour is systematic even though the numerical bias is not a single constant offset. The last value cannot be labelled a gross mistake simply because it differs from the first. There is no independent evidence of an incorrect reading or recording. Averaging across the drift would merely average differently biased states and would not eliminate the underlying cause. Hence option A is correct.
218. Two initial readings are \(9.9\) and \(10.1\) units. Their mean is \(10.0\), and their mean absolute error is \(0.1\). Two additional independent readings \(9.5\) and \(10.5\) are then included. Which statement about the four-reading set is correct?
ⓐ. The mean remains \(10.0\), but the mean absolute error increases to \(0.3\).
ⓑ. The mean becomes \(10.2\), while the mean absolute error decreases to \(0.05\).
ⓒ. The mean remains \(10.0\), and the mean absolute error must decrease because more readings were taken.
ⓓ. The mean absolute error becomes zero because positive and negative deviations cancel.
Correct Answer: The mean remains \(10.0\), but the mean absolute error increases to \(0.3\).
Explanation: The four readings are
\[
9.9,\ 10.1,\ 9.5,\ 10.5.
\]
Their sum is
\[
40.0,
\]
so the mean remains
\[
\bar x=10.0.
\]
The absolute deviations from the mean are
\[
0.1,\ 0.1,\ 0.5,\ 0.5.
\]
Therefore,
\[
\Delta x_{\text{mean}}=\frac{0.1+0.1+0.5+0.5}{4}.
\]
Hence,
\[
\Delta x_{\text{mean}}=0.3.
\]
Thus adding more observations does not mathematically guarantee that the observed mean absolute error of a particular data set must decrease. Repetition is useful for characterizing random fluctuations and stabilizing a representative estimate, but additional observations can reveal larger scatter that was not present in a small initial sample. Absolute values prevent opposite deviations from cancelling in the error estimate. Hence option A is correct.
219. Two measured quantities are
\[
x=(10.0\pm0.2)\,\text{cm},\qquad y=(14.0\pm0.3)\,\text{cm}.
\]
A new quantity is defined by
\[
Q=3x-2y,
\]
where \(3\) and \(2\) are exact. Using maximum-error treatment, what are the nominal value and maximum percentage uncertainty in \(Q\)?
ⓐ. \(2.0\,\text{cm}\) and \(30\%\)
ⓑ. \(2.0\,\text{cm}\) and \(60\%\)
ⓒ. \(58.0\,\text{cm}\) and \(2.1\%\)
ⓓ. \(2.0\,\text{cm}\) and \(10\%\)
Correct Answer: \(2.0\,\text{cm}\) and \(60\%\)
Explanation: First calculate the nominal value:
\[
Q=3(10.0)-2(14.0).
\]
Thus,
\[
Q=30.0-28.0=2.0\,\text{cm}.
\]
Because the coefficients are exact, they multiply the corresponding absolute uncertainties directly. The maximum uncertainty in the first term is
\[
3\Delta x=3(0.2)=0.6\,\text{cm}.
\]
For the second term,
\[
2\Delta y=2(0.3)=0.6\,\text{cm}.
\]
The two terms are subtracted, but maximum absolute uncertainties still add:
\[
\Delta Q=0.6+0.6=1.2\,\text{cm}.
\]
Therefore the maximum percentage uncertainty is
\[
\frac{1.2}{2.0}\times100=60\%.
\]
The close cancellation between \(30.0\) and \(28.0\) produces a small resultant value and therefore a very large relative uncertainty. Hence option B is correct.
220. Four independent measured quantities are
\[
a=(2.00\pm0.02),\quad b=(3.00\pm0.06),\quad c=(10.0\pm0.1),\quad d=(8.0\pm0.1).
\]
For
\[
Q=\frac{ab}{c-d},
\]
what are the nominal value and maximum absolute uncertainty?
ⓐ. \(3.00\) and \(0.09\)
ⓑ. \(3.00\) and \(0.30\)
ⓒ. \(3.00\) and \(0.39\)
ⓓ. \(6.00\) and \(0.78\)
Correct Answer: \(3.00\) and \(0.39\)
Explanation: Begin with the denominator:
\[
c-d=10.0-8.0=2.0.
\]
For a difference, maximum absolute errors add:
\[
\Delta(c-d)=0.1+0.1=0.2.
\]
Therefore the denominator has relative uncertainty
\[
\frac{0.2}{2.0}=0.10,
\]
or \(10\%\). For \(a\),
\[
\frac{\Delta a}{a}=\frac{0.02}{2.00}=1\%.
\]
For \(b\),
\[
\frac{\Delta b}{b}=\frac{0.06}{3.00}=2\%.
\]
The product \(ab\) therefore has maximum relative uncertainty
\[
1\%+2\%=3\%.
\]
Since the final operation is division,
\[
\%\Delta Q=3\%+10\%=13\%.
\]
The nominal value is
\[
Q=\frac{(2.00)(3.00)}{2.0}=3.00.
\]
Thus,
\[
\Delta Q=0.13(3.00)=0.39.
\]
Hence option C is correct.